The most likely culprit in this scenario is some kind of hardware issue, potentially electrical fault in the RedNet 3. This would explain why it was cycling between link DOWN and UP on the network - it's possible that shifting logic levels inside confused the ethernet controller and/or sent invalid Layer 1 signals. It's possible that during the clocking storm (21:29-21:32) the RedNet was disappearing from the network, triggering a Dante clock master election, then re-appearing, establishing itself as master, before leaving again. (This does not explain, however, why the master would cycle between Phil, Office, and StudioRed, as one would hope Dante can at least pick one as master and stick with it.) This would also explain the hot cable - normally a word clock signal is a mere 5V, not even close to sufficient for heating it up. The noise heard during the clocking storm also sounds digital, almost like dropping packets. Anecdotally, we've had issues with RedNet power supplies in the past. | |||
: | |||
= Actions = | = Actions = |